This is the abridged developer documentation for Voltaic Systems
# Technical Documentation
> Datasheets, drawings and design guides for Voltaic solar panels, the CORE off-grid power system, AxON, and custom solar panels.
This is the technical documentation for Voltaic Systems products. Includes specifications, drawings, installation guides and design rules. ## Sections * **[Solar Panels](/panels/)**: every standard panel’s specifications, drawings and 3D models. Techniques for sizing and mounting are also included here. * **[CORE Solar Systems](/core/)**: 25 to 200W off-grid solar power systems for routers, cameras and sensors. * **[AxON Solar Systems](/axon/)**: compact, plug and play 5V solar power supplies for low power outdoor devices. * **[USB Battery Packs](/usb-battery-packs/)**: the V25, V50 and V75 specifications. * **[Resources](/resources/for-ai-and-developers/)**: every spec as JSON and llms.txt for AI assistants. For pricing, availability and ordering, visit [voltaicsystems.com (opens in a new tab)](https://voltaicsystems.com). For technical questions not addressed here, [contact us (opens in a new tab)](https://voltaicsystems.com/contact-us/).
# Specifications
> AxON solar systems are compact, plug and play solar power supplies for low power outdoor devices that need a 5V output. Specifications, cables, safety and certificates for the 5W, 10W and 20W systems.
AxON solar systems are a compact, plug and play solar power supply for low power devices that need a 5V output. They’re available with 5, 10 and 20W solar panels: the [5W AxON (opens in a new tab)](https://voltaicsystems.com/5-watt-axon/), [10W AxON (opens in a new tab)](https://voltaicsystems.com/10-watt-axon/) and [20W AxON (opens in a new tab)](https://voltaicsystems.com/20-watt-axon/). For higher power and voltage devices, consider the [CORE solar systems](/core/). | Specification | [5W AxON](https://voltaicsystems.com/5-watt-axon/) | [10W AxON](https://voltaicsystems.com/10-watt-axon/) | [20W AxON](https://voltaicsystems.com/20-watt-axon/) | | ---------------------------------- | ---------------------------------------------------------------------------------------- | ---------------------------------------------------- | ---------------------------------------------------- | | System | | | | | Solar panel | P105 | P110 | P120 | | Solar panel power | 5W5.89W nominal | 10W11.8W nominal | 20W24.7W nominal | | Battery | V50 | V75 | V75 | | Battery capacity | 48Wh (13,400mAh) | 72Wh (20,100mAh) | 72Wh (20,100mAh) | | Cell configuration | 4 × 18650 Li-ion NMC (1S4P) | 6 × 18650 Li-ion NMC (1S6P) | 6 × 18650 Li-ion NMC (1S6P) | | Bracket | BK102 | BK103 | BK103 | | Mass | 0.9kg | 1.4kg | 1.8kg | | Electrical | | | | | Input voltage range | 5–6V | | | | Output | 5V, 2AM8 bulkhead connector | | | | Protections | Short circuit, reverse polarity, over current, over and under temperature, under voltage | | | | Output cable options | M8 to USB-C (W328) or M8 to bare leads (W265) | | | | Temperature | | | | | Input (charging) temperature range | 0–45°C | | | | Output temperature range | −15–60°C | | | Power production depends on a number of factors, including location, time of year, temperature, shading and general weather variability. See [System Sizing](/axon/sizing/). ## Cable Details AxON systems use Voltaic’s [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) and [V75 (opens in a new tab)](https://voltaicsystems.com/v75) battery packs in a waterproof case. On the outside of the case, there’s an M8 bulkhead connector. From the bulkhead, you can connect to your device with one of Voltaic’s cables, terminating in USB-C ([W328 (opens in a new tab)](https://voltaicsystems.com/W328)) or bare leads ([W265 (opens in a new tab)](https://voltaicsystems.com/w265)). Note that USB-C cables typically don’t have good waterproofing. Consider taking extra steps to limit their exposure to water and humidity. ## Safety Precautions Caution * Do not expose the AxON to high heat or direct flame. * Do not throw it in the trash or incinerate it. * Do not get the internal battery wet, store it in high humidity or otherwise short-circuit it. * Do not disassemble or tamper with the battery. * Do not wire multiple AxON systems in parallel or in series. ## Certifications The safety data sheet (MSDS), [UN38.3 (opens in a new tab)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) test summary, and RoHS and REACH declarations are available on request. [Contact us (opens in a new tab)](https://voltaicsystems.com/contact-us/) with the battery SKU.
# Installation
> Installing a Voltaic AxON solar system: charging the battery from a USB charger, mounting the bracket on a pole, connecting the M8 power cable, turning the battery on and securing the cables. Includes the installation instructions (PDF).
Mount the system on a pole, connect the M8 power cable, turn the battery on and secure the cables. AxON solar systems provide 5V Always On output to outdoor devices, and the [5W (opens in a new tab)](https://voltaicsystems.com/5-watt-axon/), [10W (opens in a new tab)](https://voltaicsystems.com/10-watt-axon/) and [20W AxON (opens in a new tab)](https://voltaicsystems.com/20-watt-axon/) install the same way. This page has the same content as the [AxON installation instructions (PDF)](/manuals/AxON_installation_instructions.pdf). ## Before You Start Each system is a solar panel and a waterproof battery on one bracket, plus an M8 power cable that ends in USB-C or bare leads. | SKU | Panel power | Battery capacity | | ------------------------------------------------------ | ----------- | ---------------- | | [K-P105-V50](https://voltaicsystems.com/5-watt-axon/) | 5W | 48Wh / 13,400mAh | | [K-P110-V75](https://voltaicsystems.com/10-watt-axon/) | 10W | 72Wh / 20,100mAh | | [K-P120-V75](https://voltaicsystems.com/20-watt-axon/) | 20W | 72Wh / 20,100mAh | See [Specifications](/axon/) for the full details of each system. ### Hardware Required (Not Included) * 2 [band clamps (opens in a new tab)](https://www.amazon.com/dp/B0CPVMSSWB/) (a steel strap and ratchet tool, which pulls the strap tight around the pole), or 2 U-bolts for 16 to 72mm (0.75 to 2.5 in) poles * Zip ties ### Charging from AC / Mains You can charge the battery from a USB charger without removing it from the case. 1. Loosen the gland and remove the solar panel cable from the battery. 2. Connect a [W179 (opens in a new tab)](https://voltaicsystems.com/W179/) cable from a USB charger to the solar panel input. 3. When you’re done, replace the solar panel cable firmly in the solar panel input. Tighten the gland to restore the waterproof connection.  The LEDs light up in sequence until the battery is full. Once it’s full, all four LEDs show solid. Caution We suggest testing the connection to your device before you mount the system. ## Step 1: Install the System on a Pole Install the solar panel system on a pole with U-bolts or band clamps. In the Northern Hemisphere, the solar panel should face south, away from any objects that might shade it, like trees or buildings. If the panel is shaded for a meaningful part of the day, the system won’t work well. See [System Sizing](/axon/sizing/#step-4-check-shading-on-shademap) for checking shade at your site.  ## Step 2: Connect the Power Output Cable Align the pins of the M8 power cable and the Power Output. Press them together and twist the M8 power cable tight.   ## Step 3: Turn the Battery On and Connect Your Device Press the Power Button until the LED indicator lights turn on. A double tap turns them off, if you’re putting the battery into storage. When the battery is connected to your device, you should see the device turn on. The battery LEDs blink while the battery charges and show its charge progress.  | LEDs lit | Charge level | | -------- | ------------ | | 1 | 25% | | 2 | 50% | | 3 | 75% | | 4 | 100% | ## Step 4: Organize and Neaten Cables Use zip ties to organize and tighten all cables. Cables should be secure in high winds. ## Optional Steps * To read the battery voltage from the output cable, see [System Monitoring](/axon/monitoring/).
# System Monitoring
> Monitoring Voltaic AxON solar systems. Reading the battery voltage from the W328 USB-C and W265 bare leads output cables.
## Reading the Battery Level An analog battery voltage is available on both output cables, so you can use it to gauge the battery’s state of charge: * [W328 (opens in a new tab)](https://voltaicsystems.com/W328) M8 to USB-C cable: the sideband use (SBU) pins of the USB-C plug. * [W265 (opens in a new tab)](https://voltaicsystems.com/w265) M8 to bare leads cable: the yellow and white leads, measured against ground. The blog post [Updated USB-C PD and Always On for V25, V50 and V75 Batteries (opens in a new tab)](https://blog.voltaicsystems.com/updated-usb-c-pd-and-always-on-for-v25-v50-v75-batteries/) explains the SBU voltage.
# System Sizing
> How to size a Voltaic AxON solar system: measure your device's power consumption, choose a 5W, 10W or 20W system from December solar energy at your location, and check temperature limits and shading.
We recommend placing AxON systems in locations with direct sunlight and minimal shading. If the panel receives shading from trees or buildings, it likely won’t perform well. The key to sizing the system is understanding the power consumption of your device and the available solar energy at your location. The [CORE System Sizing](/core/sizing/) page has more detailed sizing logic; this page is a simplified version. ## Step 1: Determine Your Power Consumption in Watt Hours If possible, don’t rely only on the manufacturer’s datasheet, as its figures are often on the high side. We suggest measuring the power consumption with a USB multimeter, available on Amazon. If your device uses 1.2Wh while running for 3 hours, its power consumption is about 9.6Wh per day. The popular PUC by BirdWeather consumes 7 to 8Wh per day. ## Step 2: Choose a System Based on Daily Power Consumption and Location This map from the National Renewable Energy Laboratory (NREL) shows average daily solar radiation in December, and covers only the US. If you’re outside the US, you can cross-reference [global insolation maps (opens in a new tab)](https://www.amerescosolar.com/wp-content/uploads/insolation_mapweb.pdf). Select a system that produces more energy in December than your device consumes. We recommend oversizing where possible.  ### Expected Energy Available in December Watt hours per day, by region on the map. | Region (map color) | [5W AxON (opens in a new tab)](https://voltaicsystems.com/5-watt-axon/) | [10W AxON (opens in a new tab)](https://voltaicsystems.com/10-watt-axon/) | [20W AxON (opens in a new tab)](https://voltaicsystems.com/20-watt-axon/) | | ---------------------------------------------------- | ----------------------------------------------------------------------- | ------------------------------------------------------------------------- | ------------------------------------------------------------------------- | | Light green (desert Southwest) | 12 | 24 | 36 | | Green (South and lower Midwest) | 9 | 18 | 27 | | Light blue (Northeast and Upper Midwest) | 6 | 12 | 18 | | Dark blue (Pacific Northwest and Great Lakes region) | 3.5 | 7 | 12 | A few notes: * These figures include losses from the charge circuit, the transformation of electrical energy (solar panel) to chemical energy (battery), and output regulation. * The 20W system doesn’t produce double the energy of the 10W system, because the battery input is capped at 10W. * No one gets upset about having too much solar power. Size up if possible. ## Step 3: Understand Temperature Limitations AxON batteries don’t charge below freezing (0°C). If there are multiple days below freezing, the system is likely to lose power. It recovers when the temperature goes above freezing. For critical systems, consider the larger [CORE](/core/) line of products. ## Step 4: Check Shading on ShadeMap Solar panel performance drops if the panel isn’t facing south or is shaded. Before deploying, check your location on [ShadeMap (opens in a new tab)](https://shademap.app) in June and December.
# Troubleshooting
> Troubleshooting a Voltaic AxON solar system: common causes, checking that the battery is charging, a device that doesn't charge and fault lights.
## Common Causes If your AxON system stops charging your device, there are several potential root causes: * The battery is drained: the power output to the device exceeds the production from the solar panel. This could be from an undersized system, poor solar panel placement, or extended sub-freezing or overcast conditions. * The solar system is working, but the end device has an issue. * The battery has failed. This is more likely than a solar panel failure. * The solar panel isn’t working. This is rare, but possible. ## Checking the Battery  Press the Power Button once to make sure the output is on. AxON systems ship with the battery turned off. Make sure the system is in a sunny location with the panel pointed at the sun. Look at the LED indicators: if they blink in sequence, the battery is charging. If 1 or more of the 4 LEDs are lit, the battery has power and should be able to power your device. If just 1 LED is lit, the battery is close to empty and the system is likely underpowered. Consider: * Moving the system to a sunnier, south-facing location * Measuring the power consumption of your device accurately, to make sure you have the right size system. See [System Sizing](/axon/sizing/). * Increasing the size of the solar panel, the battery or both If no LEDs light up after you press the Power Button, or from the solar panel, the battery isn’t getting a charge. We suggest: 1. Disconnect the power output cable. 2. Loosen the gland around the Solar Panel Input, then disconnect and reconnect the solar panel. 3. If the battery still isn’t charging, try connecting it to a USB wall charger with a [W179 (opens in a new tab)](https://voltaicsystems.com/W179/) cable. See [Charging from AC / Mains](/axon/installation/#charging-from-ac--mains). ## Device Not Charging If the battery has a charge but doesn’t charge your device, we suggest: * Check whether the device charges from a wall charger. * Swap the output cable for another one. ## Fault Indication If all 4 LEDs flash several times, there could be a fault. Disconnect the M8 power cable and press the Power Button. If the flashing continues, also disconnect the Solar Panel Input and press the Power Button again. If a cable is causing the fault, replace it.
# Specifications
> Voltaic CORE solar power systems are plug and play power supplies for outdoor electronic devices such as networking equipment, cameras and environmental monitoring. Specifications, cables and safety precautions for the V102, V107 and V112 batteries and P152, P150 and P151 solar panels.
Voltaic’s CORE solar power systems are plug and play power supplies for outdoor electronic devices including networking equipment, cameras and environmental monitoring devices. CORE solar systems are pre-assembled and include mounting hardware. Typical power consumption ranges from 0.5 to 15 Watts continuous. For lower power devices using 5V, see our [AxON solar systems](/axon/). The waterproof battery uses long life LiFePO4 (LFP) cells and has an integrated MPPT charge controller. This design eliminates the need for a large enclosure and reduces weight and complexity. Solar panel and battery size can be adjusted to match the available power to the system load. Battery health can be monitored from raw battery voltage, an optional RS-485 feed or the Voltaic IoT module. The [CORE Solar Power Systems datasheet (PDF)](/manuals/CORE_solar_power_systems_datasheet.pdf) has these specifications in one file. ## System Kits | System SKU | Solar panel power (W) | Battery capacity (Ah) | Battery voltage options | Mass (kg) | | ------------------------------------------------------------------------------- | --------------------- | --------------------- | ------------------------- | --------- | | [K-P152-V102 (opens in a new tab)](https://voltaicsystems.com/25-watt-core/) | 25 | 18 | 12V Unregulated, 5V | 6 | | [K-P150-V102 (opens in a new tab)](https://voltaicsystems.com/50-watt-core/) | 50 | 18 | 12V Unregulated, 5V | 8 | | [K-P150-V107 (opens in a new tab)](https://voltaicsystems.com/50-watt-core/) | 50 | 60 | 12V Unregulated, 5V, PoE+ | 14 | | [K-P151-V107 (opens in a new tab)](https://voltaicsystems.com/100-watt-core/) | 100 | 60 | 12V Unregulated, 5V, PoE+ | 21 | | [K-P151-V112 (opens in a new tab)](https://voltaicsystems.com/100-watt-core/) | 100 | 100 | 12V Unregulated, 5V, PoE+ | 29 | | [K-P151X2-V107 (opens in a new tab)](https://voltaicsystems.com/200-watt-core/) | 200 | 60 | 12V Unregulated, 5V, PoE+ | 27 | | [K-P151X2-V112 (opens in a new tab)](https://voltaicsystems.com/200-watt-core/) | 200 | 100 | 12V Unregulated, 5V, PoE+ | 34 | Solar panel power is rounded to the product rating. The exact nominal values are in the [Solar Panels](#solar-panels) table below. ## Batteries  ### Standard Temperature Range | Battery | [V102 (opens in a new tab)](https://voltaicsystems.com/V102/) | [V107 (opens in a new tab)](https://voltaicsystems.com/V107/) | [V112 (opens in a new tab)](https://voltaicsystems.com/V112/) | | ------------------------ | ------------------------------------------------------------- | ------------------------------------------------------------- | ------------------------------------------------------------- | | Nominal capacity | 18Ah / 230Wh | 60Ah / 768Wh | 96Ah / 1229Wh | | Max input/output current | 10A | 15A | 15A | | Maximum solar panel | 100 Watt | 200 Watt | 200 Watt | | Dimensions | 104 x 147 x 237mm | 104 x 147 x 538mm | 104 x 147 x 736mm | | Cell configuration | 4S 3P LFP 32700 | 4S 10P LFP 32700 | 4S 16P LFP 32700 | | Mass | 4kg | 9kg | 16kg | | All batteries | | | ----------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | Charge controller | Maximum Power Point Tracking (MPPT) - 6mA self consumption, up to 97% efficient | | Input connectors | MC4 | | Standard output connector | M16 4-pin cable | | Input voltage range | 14.5V - 25V | | Output temperature range | -20 - 60°C | | Input temperature range | 0 - 60°C | | Standard output voltage range | 12.4V - 14.6V | | Output wire options | W261 M16 to M16 Extension - 1.5m [W262 (opens in a new tab)](https://voltaicsystems.com/W262/) M16 to Bare Leads - 1.5m [W276 (opens in a new tab)](https://voltaicsystems.com/W276/) M16 5521 Barrel Jack - 1.5m | | Optional output SKU | [C304 (opens in a new tab)](https://voltaicsystems.com/C304/) 5V Regulator [C403 (opens in a new tab)](https://voltaicsystems.com/C403) 48V PoE Injector | | Protections | Short Circuit, Reverse Polarity, Over Current, Over / Under Temperature, Under Voltage | ## Solar Panels | Solar panel | [P152 (opens in a new tab)](https://voltaicsystems.com/P152/) | [P150 (opens in a new tab)](https://voltaicsystems.com/P150/) | [P151 (opens in a new tab)](https://voltaicsystems.com/P151/) | | ---------------------------------- | --------------------------------------------------------------- | --------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------- | | Compatible bracket | [BK108 (opens in a new tab)](https://voltaicsystems.com/BK108/) | [BK108 (opens in a new tab)](https://voltaicsystems.com/BK108/) | [BK110 (opens in a new tab)](https://voltaicsystems.com/BK110/) (or [BK111 (opens in a new tab)](https://voltaicsystems.com/BK111/) for x 2) | | Wp - Maximum power | 28.7W | 57.8W | 115.5W | | Vp - Voltage at max power | 18.0V | 18.0V | 18.0V | | Voc - Open-circuit voltage | 20.7V | 20.7V | 20.7V | | Ip - Current at max power | 1.60A | 3.21A | 6.43A | | Isc - Short-circuit current | 1.67A | 3.37A | 6.73A | | Solar cell efficiency | 23.2% | 23.2% | 23.2% | | Number of cell pieces | 30 | 30 | 30 | | Dimensions | 307 x 507 x 30mm | 586 x 507 x 30mm | 586 x 980 x 30mm | | Mass | 1.9kg | 3.2kg | 6.2kg | | Wire length (including connectors) | 710mm | 710mm | 1000mm | Electrical values are nominal: the rated values from the spec sheet, at [Standard Test Conditions](/panels/#standard-test-conditions). Real-world output is usually slightly lower. For full performance details, see each panel’s technical datasheet on its product page. | All panels | | | ----------------- | ---------- | | Connector type | MC4 | | Temperature range | -40 - 80°C | ## Cable Details ### Power The power cables use 4-pin M16 connectors. The batteries are capable of delivering 10A (V102) to 15A (V107, V112). Any cables paired to these should be capable of managing that current or should integrate a fuse. Pins 1 and 4 deliver power to the device or our regulator. Pins 2 and 3 function as an on switch. Connecting the cable to the battery turns on the charge controller.  Output cable options: * **W261**: M16 to M16 extension, 1.5m * **W262**: M16 to bare leads, 1.5m * **W276**: M16 to 5521 barrel jack, 1.5m ### Data Battery information is available via a 4-pin M8 connector on the front of the enclosure. The pinout, Modbus parameters and registers are in the [RS-485 Guide](/core/monitoring/#rs-485-guide). ### Solar Panel Cables The solar panels and batteries connect to each other using industry standard MC4 style connectors. Joiner cables are available to place two sets of panels in parallel. 1m extension cables are also available. ## Storage and Disposal If not using the battery, disconnect all cables from the battery and store it in a dry location between 10°C and 25°C at 40 to 60% state of charge. If the power cable is left connected, the charge controller will stay on and the battery will drain completely, potentially damaging the cells. Check the charge status every 6 months. The battery contains lithium iron phosphate cells and should not be included with trash. The battery should be disposed of with a local battery recycler. ## Safety Precautions Caution * Do not install in unsafe weather conditions (rain, snow, ice). * Do not expose to high heat or direct flame. * Do not throw in trash or incinerate. * Do not disassemble or tamper with the battery. * Do not short circuit the output terminals. * Do not submerge the battery in water.
# Installation
> Installing a Voltaic CORE solar power system. Charging the battery from AC mains, mounting the V102, V107 and V112 batteries on the BK108, BK110 and BK111 brackets or a pole, connecting cables in the right order, securing wires, and the PoE, 5V regulator and monitoring options.
A CORE system is a solar panel on a bracket, a CORE battery mounted to the bracket or the pole, and two cable connections. This page follows the instruction sheet packed with the [V102 (opens in a new tab)](https://voltaicsystems.com/V102/), [V107 (opens in a new tab)](https://voltaicsystems.com/V107/) and [V112 (opens in a new tab)](https://voltaicsystems.com/V112/) batteries ([download the PDF](/manuals/CORE_installation_instructions.pdf)). The three batteries install the same way and differ in capacity and length. ## Before You Start The battery ships with its cables fitted: two MC4 cables for the solar panel and one power output cable. The L brackets, bracket bolts and battery rails on the back are the mounting hardware.  ### Tools * 6mm hex key (included) * Adjustable wrench * [Steel strap and ratchet (opens in a new tab)](https://www.amazon.com/dp/B0CPVMSSWB/), for a pole mount * Zip ties ### Charging from AC / Mains The CORE batteries can be charged from AC / mains power using the DC Constant Current Charger ([C312 (opens in a new tab)](https://voltaicsystems.com/C312)). The battery has a maximum power point tracking (MPPT) charge controller, which adjusts the input voltage to find the solar panel’s maximum power point. If you try using a standard, constant voltage charger, it won’t work. Connect the output cable to the battery to turn it on. Caution Test the battery and your device together before you mount the bracket and panel. A fault is easier to find on the bench than on a pole. ## Step 1: Install the Panel and Bracket Instructions are included with the bracket. Which bracket you have depends on the system size. | Bracket | Systems | Instructions | | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------ | --------------------------------------------------------------------------------------------- | | [BK108 (opens in a new tab)](https://voltaicsystems.com/BK108/) | [25W (opens in a new tab)](https://voltaicsystems.com/25-watt-core/) and [50W (opens in a new tab)](https://voltaicsystems.com/50-watt-core/) CORE | [BK108 assembly instructions (PDF)](/manuals/BK108_assembly_instructions.pdf) | | [BK110 (opens in a new tab)](https://voltaicsystems.com/BK110/) and [BK111 (opens in a new tab)](https://voltaicsystems.com/BK111/) | [100W (opens in a new tab)](https://voltaicsystems.com/100-watt-core/) and [200W (opens in a new tab)](https://voltaicsystems.com/200-watt-core/) CORE | [BK110 and BK111 assembly instructions (PDF)](/manuals/BK110_BK111_assembly_instructions.pdf) | ## Step 2: Mount the Battery In every position, the battery’s cables point down. That keeps water running away from the glands. ### V107 on the BK110 Remove the long bolts from the back of the battery. Line the battery up on the bracket so the L brackets line up with the holes. The L brackets slide along the battery rails if they need to shift. Reinsert the bolts and tighten the flanged lock nuts.  ### V102 or V107 on the BK108 With the upper bracket bolt in place, hang the battery on the hook on the bracket. Pass the second bracket bolt through and tighten both bolts. The battery’s wires face down.  ### V112 on a Pole Remove the bracket bolts. Strap the battery to the pole with stainless steel straps passed through the L brackets on the back of the battery. Confirm the solar panel cables reach the battery before you tighten the straps. The battery’s wires face down.  ## Step 3: Connect the Cables Connect the power output cable to your device first, then the solar panel. Connecting the power output cable turns the battery on, and the charge controller light turns orange. If your system has Power over Ethernet, see [PoE](#poe) below. With the power output cable connected and the charge controller on, connect the MC4 solar panel cables. They are keyed to the positive and negative connections, so push each one until it clicks. Outside in the sun, the green light on the charge controller blinks to show it is charging.  ## Step 4: Secure the Cables Bundle the cables neatly and zip tie them to the bracket so they can’t move in the wind. If the battery is mounted horizontally, leave a drip loop in the solar panel and power cables so water runs off the loop rather than into the glands.  ## Indicator Lights The charge controller lights show through the front of the battery. Green is the charging state, amber is system on or low battery, and red is no output or a protection fault. The full table is on the [Troubleshooting page](/core/troubleshooting/#system-indicator-lights). ## Options ### Remote Monitoring Scan the QR code on the side of the battery to see its status: charge level, solar panel output and device power output. See [System Monitoring](/core/monitoring/) for the dashboard.  ### 5V Regulator The [C304 regulator (opens in a new tab)](https://voltaicsystems.com/C304/) converts the battery’s unregulated 12V output to 5V. It is available with a USB-C or a Micro-USB connector.  ### PoE A Power over Ethernet (PoE) injector, the [C403 (opens in a new tab)](https://voltaicsystems.com/C403/), can be installed inside the battery enclosure on request. The injector has a power port and a data port. **Connect the power cable or cap, then the solar panels.** As in Step 3, the cap or power cable turns the charge controller on and the orange light comes on. The green light blinks once the solar panels are connected outside in the sun.  **Connect the Ethernet cables.** Two compatible cables are included. If you need more length, use outdoor-rated patch cables without a strain relief or boot, because not every Ethernet cable fits through the waterproof housing. Remove the caps on the PoE ports, pass the cable through the housing, reassemble the housing and tighten it securely. If you don’t use the data port, plug it to keep water out.  ## Mounting Hardware ### Stainless Straps vs Hose Clamps We recommend U-bolts or ¾-inch stainless steel straps for the 25W and 50W CORE systems. For 100W and 200W systems, we recommend steel straps. Hose clamps with a worm gear are inexpensive and easy to use, but can corrode and fail under high loads.
# System Monitoring
> Monitoring Voltaic CORE systems. Battery protection behavior, battery voltage, the Voltaic IoT module and the RS-485 data port.
## Battery Protection Behavior CORE batteries have both a charge controller and a BMS to protect the battery against overcharge, overdischarge, short circuit and charging outside of acceptable temperature ranges. The charge controller provides the primary, software-based protection, while the BMS is a hardware-controlled system acting as a backup. ### Low Voltage and Over Voltage Protection The battery has both a protection value and a recovery value. These values are intentionally different in order to prevent the charging or the load from cycling on and off. | Protection Setting | Description | Action | Charge Controller Value | BMS Value | | ------------------ | ----------------------- | --------------- | ----------------------- | --------------------------------- | | LVP | Low Voltage Protection | Turn Load Off | 12.4 V | 2.3 ± 0.1 V per parallel string | | LVR | Low Voltage Recovery | Turn Load On | 13.1 V | 2.7 ± 0.1 V per parallel string | | OVP | Over Voltage Protection | Stop Charging | 14.0 V | 3.65 ± 0.05 V per parallel string | | OVR | Over Voltage Recovery | Resume Charging | 13.3 V | 3.55 ± 0.05 V per parallel string | Here is how these charge controller protections operate during an example charge cycle. CORE battery protection: LVP / LVR / OVP / OVR ### Low Temperature and Over Temperature Protection The temperature protections are as follows. | Protection Setting | Description | Action | Charge Controller Value | BMS Value | | ------------------ | --------------------------- | --------------- | ----------------------- | ---------- | | LTP | Low Temperature Protection | Stop Charging | 0 °C | NA | | LTR | Low Temperature Recovery | Resume Charging | \~2 °C | NA | | OTP | Over Temperature Protection | Stop Charging | 60 °C | 75 ± 5 °C | | OTR | Over Temperature Recovery | Resume Charging | \~55 °C | 53 ± 14 °C | ## Voltage Only This is the most basic monitoring option. The output from the battery is unregulated, so you can get some data points on battery charge level by reading the battery output voltage. It is hard to accurately assess charge using this method, as the charge curve for LFP cells is relatively flat and the voltage increases when charging from the solar panel. ## Voltaic IoT Module Voltaic makes an optional IoT module that connects to the RS-485 output on the battery. It reads information from the charge controller and sends data over cellular to a dashboard. Data includes: * Battery voltage * Output current to device * Solar panel voltage * Input current from solar panel * Battery temperature From this data, we are able to estimate battery state of charge (SoC). The dashboard can be used to evaluate the health of a single battery or a fleet of batteries and is valuable in troubleshooting solar systems. See [Troubleshooting](/core/troubleshooting/) for more details. ## RS-485 Guide If you have your own connectivity, you can read the charge controller over RS-485 and report to your own dashboard. This section covers the hardware, the Modbus parameters, the registers and example code. ### Overview The charge controllers in CORE systems come in two versions: a 10A version for the 18Ah battery ([V102 (opens in a new tab)](https://voltaicsystems.com/V102/)) and a 15A version for the 60Ah and 100Ah batteries ([V107 (opens in a new tab)](https://voltaicsystems.com/V107/), [V112 (opens in a new tab)](https://voltaicsystems.com/V112/)). Both have a 4-pin output for RS-485 Modbus RTU half-duplex communication. ### Hardware The RS-485 Modbus feed comes out of a 4-pin female M8 connector on the front of the battery. The feed has two serial pins (A and B), so it is half-duplex: it can’t transmit and receive at the same time. The wiring of the M8 extension cables changed to improve consistency across battery and device connections. In the legacy wiring the A and B signals were the other way round: pin 3 was B and pin 4 was A. Now pin 3 is A and pin 4 is B. If you connect a new cable to an older system, check the pin assignments on the RS-485 lines, because swapped A and B lines stop the devices communicating. **Current configuration** | Pin | Name | Description | | --- | ---------- | ------------------------------- | | 1 | V+, red | Unregulated 12V battery voltage | | 2 | GND, black | Ground | | 3 | A, yellow | Half-duplex RS-485 serial pin | | 4 | B, white | Half-duplex RS-485 serial pin |  **Legacy configuration** | Pin | Name | Description | | --- | ---------- | ------------------------------- | | 1 | V+, red | Unregulated 12V battery voltage | | 2 | GND, black | Ground | | 3 | B, yellow | Half-duplex RS-485 serial pin | | 4 | A, white | Half-duplex RS-485 serial pin |  If the device reading the RS-485 data has its own power source, you don’t need to connect the V+ pin. The RS-485 signal depends on relative voltages, so connect the GND pin to the reading device’s ground. RS-485 is a serial hardware format. If you route the feed to a microcontroller or another UART device, it needs an adapter IC. Some adapter ICs need a HIGH/LOW pin to switch between transmitting and receiving. ### RS-485 Parameters The charge controller uses standard Modbus RTU. Set these parameters in whichever Modbus library you use: * 9600 baud * 8 data bits * 1 stop bit * No parity bit * No flow control ### Hex Format The charge controller uses a call-and-response protocol between primary and secondary devices, in hexadecimal. A register is two pairs of hex values (AB CD). **Call.** This call reads the register that holds the battery voltage:
```plaintext
01 04 30 A0 00 01 XX XX
```
| Bytes | Meaning | | ------- | ------------------------------------------------------------------------------------ | | `01` | The charge controller device ID. The default is 01 and can be changed on the device. | | `04` | The Modbus function code. 04 reads an input register. | | `30 A0` | The register to read or write. The registers are listed below. | | `00 01` | The number of registers to read, usually 1. | | `XX XX` | Cyclic redundancy check (CRC). Most Modbus libraries generate it. | **Response.** The charge controller’s reply to that call looks like this:
```plaintext
01 04 00 02 05 46 XX XX
```
| Bytes | Meaning | | ------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | `01` | The charge controller device ID. | | `04` | The Modbus function code, echoed. | | `00 02` | The number of data bytes returned: twice the number of registers. | | `05 46` | The register value. Many values are stored at 100 times their true value, so 05 46, which is 1350 in decimal, means 13.5V. A negative value is sent as the maximum register value (0xFFFF, 65535) minus the magnitude: a battery current of −2A (current leaving the battery) is reported as 65335, which is 65535 − 200. | | `XX XX` | CRC reply. Most Modbus libraries check it. | **Modbus function codes** | Code | Function | | ---- | -------------------------------- | | 0x02 | Read discrete inputs | | 0x03 | Read holding registers | | 0x04 | Read input registers | | 0x05 | Write single coil | | 0x06 | Write single holding register | | 0x10 | Write multiple holding registers | ### Charge Controller Registers **Read-only registers** hold the charge controller’s real-time measurements. They can’t be written over RS-485. Every value carries a ×100 multiplier: the true value is the read value divided by 100. | Register | Function code | Register code | Decimal code | Multiplier | | ---------------------------- | ------------- | ------------- | ------------ | ---------- | | Battery voltage (V) | 0x04 | 0x30A0 | 12448 | 100 | | Battery current (A), signed | 0x04 | 0x3047 | 12359 | 100 | | System input voltage (V) | 0x04 | 0x304E | 12366 | 100 | | System input current (A) | 0x04 | 0x304F | 12367 | 100 | | Load voltage (V) | 0x04 | 0x304A | 12362 | 100 | | Load current (A) | 0x04 | 0x304B | 12363 | 100 | | Environment temperature (°C) | 0x04 | 0x30A2 | 12450 | 100 | | Controller temperature (°C) | 0x04 | 0x3037 | 12343 | 100 | | Battery status | 0x04 | 0x3033 | 12339 | | Battery current is a signed value: decimal 0 to 32767 is positive, and 32768 to 65535 is negative, where 65535 is −1, 65534 is −2, and so on. **Reading battery status.** Register 0x3033 holds the temperature and voltage status. Convert the read value to hex and split it: the first two hex digits are the temperature protection state and the last two are the voltage protection state. | Digits | Value | Meaning | | --------- | ----- | --------------------------- | | First two | 0 | Normal | | First two | 1 | High temperature protection | | Last two | 0 | Normal | | Last two | 1 | Over voltage protection | | Last two | 2 | Low voltage | | Last two | 3 | Low voltage protection | For example, a reading of `00 03` means normal temperature and low voltage protection. **Read/write registers** can be read to check the charge controller’s settings, or written to change its behaviour. | Register | Function code | Hex value | Decimal value | Data | | --------------------- | --------------------------- | --------- | ------------- | ------------------------------------- | | Battery output switch | 0x05 | 0 | 0 | 1 turns the output on, 0 turns it off | | Device ID | 0x03 to read, 0x06 to write | 0x9020 | 36896 | Default 1, range 1 to 247 | ### Modbus Libraries and Example Code The easiest way to send and receive data over RS-485 is a Modbus library. **Python on a desktop computer.** [minimalmodbus (opens in a new tab)](https://pypi.org/project/minimalmodbus/) is a straightforward library for RS-485. You need an RS-485 USB adapter to talk to the controller. This example reads from and writes to the charge controller:
```python
import minimalmodbus
import serial
instrument = minimalmodbus.Instrument('COM12', 1) # COM port depends on the computer and port used
instrument.serial.baudrate = 9600
instrument.serial.bytesize = 8
instrument.serial.parity = serial.PARITY_NONE
instrument.serial.stopbits = 1
instrument.serial.timeout = 1
instrument.mode = minimalmodbus.MODE_RTU
reg = instrument.read_register(36898, 0, 3) # Reads the low voltage register
# Arguments: decimal register, number of decimals in the data, function code
print("Low Voltage Protection: ", reg / 100)
reg = instrument.write_bit(0, 1, 5) # Writes the load output value to ON
# Arguments: decimal register, value to store, function code
if reg is None:
print("Write Success")
```
**C++ on an Arduino-compatible microcontroller.** [ModbusMaster (opens in a new tab)](https://www.arduino.cc/reference/en/libraries/modbusmaster/) is a good option. This example assumes an RS-485 adapter that needs a pin (pin 13) to signal whether it is sending or receiving:
```cpp
#include
#define Battery_Voltage_Address 0x30A0 // Register we want to read
#define MAX485_DE D13 // Send/receive signal
#define usbSerial Serial
ModbusMaster node; // Instantiate the ModbusMaster object
double load = 1; // Setting load output to ON
void preTransmission1() // Sets the pre-transmission signal (transmit)
{
digitalWrite(MAX485_DE, 1);
}
void postTransmission1() // Sets the post-transmission signal (receive)
{
digitalWrite(MAX485_DE, 0);
}
void setLoad() { // Turns the controller output ON or OFF
if (load == 1) {
Serial.println("Output ON");
node.writeSingleCoil(0x0000, 1); // Write the value to the register
delay(1000);
} else {
Serial.println("Output OFF");
node.writeSingleCoil(0x0000, 0);
delay(1000);
}
}
int readModbusRegister(uint16_t regAddress)
{
uint8_t result;
uint16_t data;
int value = -1;
int numRead = 1;
Serial.print("Reading Modbus Register at address: 0x");
Serial.println(regAddress, HEX);
result = node.readInputRegisters(regAddress, numRead); // Read the register
if (result == node.ku8MBSuccess) { // Check for success
Serial.print(" Response Bytes: ");
for (uint8_t i = 0; i < numRead; i++) {
Serial.print(node.getResponseBuffer(i), HEX);
Serial.print(" ");
}
Serial.println();
data = node.getResponseBuffer(0);
value = data;
} else { // Else error
Serial.print("Error reading input register " + String(regAddress) + ". Error code: ");
Serial.println(result, HEX);
}
delay(1000);
return value; // Return the register value
}
void setup()
{
pinMode(MAX485_DE, OUTPUT); // Set pin modes and values
digitalWrite(MAX485_DE, 0);
Serial.begin(9600); // Begin serial communication
Serial1.begin(9600);
node.begin(1, Serial1); // Modbus slave ID 1, Serial1
// Callbacks configure the RS-485 transceiver direction
node.preTransmission(preTransmission1);
node.postTransmission(postTransmission1);
}
void loop()
{
int res = 0;
res = readModbusRegister(Battery_Voltage_Address); // Read and print the register
delay(1 * 60 * 1000); // Wait 1 minute
}
```
The scripts are also available standalone on request. For help with an integration, [contact us (opens in a new tab)](https://voltaicsystems.com/contact-us/).
# System Sizing
> How to size a Voltaic CORE system. Estimate solar energy and power consumption, and account for shading and cold temperatures.
## Basic Approach The solar panel needs to generate more power, after losses, than the system consumes per day. The battery needs enough storage, or buffer, to continue powering the device when solar production falls below average due to weather conditions. To minimize “loss of load”, we recommend that the panel is sized to generate at least 1.5 times the expected power consumption during the worst month of the year. The battery should be sized to run the device, without any solar power, for generally 5 days. This number will vary based on regional climate as well as tolerance for potential outages. ## Estimate Available Solar Energy We use the [PVGIS (opens in a new tab)](https://re.jrc.ec.europa.eu/pvg_tools/en/) tool. We look at the available energy during the worst months of the year, which tend to be December and January in the northern hemisphere. ## Estimate Power Consumption Manufacturer estimates are a good starting point, although they are frequently high. Connect the system to a bench top power supply, or install a system with our IoT monitor, to get a more accurate result. Examine variables that can reduce power consumption: * Select an alternate vendor with a lower power consumption device. * Adjust variables like frame rate, data transmission rate and IR lights. * Set the system on a timer if it is not needed 24 hours per day. Every watt of reduction in power can lead to a smaller solar system or higher uptime. ## Impact of Shading Shading from buildings or trees can significantly impact uptime. It can also shift over the year, so an installation that gets full sun in July receives sun only part of the day in October when the sun is lower in the sky. When shaded, power production from a panel may drop by 10X. When evaluating a site that might have shade, we recommend a few tools: * [shademap.app (opens in a new tab)](https://shademap.app) can tell you, by time of year, how many hours of direct sun a panel would receive, and evaluate alternative locations. You can use this value to discount the expected power production from PVGIS. * Height calculation: walks through the math to calculate the distance needed between a wall and solar panel to avoid shading from the building. If the solar panel is shaded for all or part of the day, the options to maintain uptime are: * Move the panel to a location with better exposure. * Position the panel higher up on a pole. * Increase the panel size. This only works if there is some direct sunlight. Increasing panel size if shaded 100% of the day rarely works. * Decrease power consumption. ## Impact of Cold Temperature Our standard batteries (V102, V107, V112) stop charging at 0°C but continue discharging to -20°C. If there is an extended period where temperatures rarely exceed freezing, the battery will fully discharge and the output will cut off. The battery will resume charging when the temperature exceeds freezing, but this could mean long outages depending on the location. Options for environments that see below freezing temperatures: * Increase the size of the solar panel and battery above the minimums if highs go below freezing infrequently. * If below freezing high temperatures are frequent (see [Weather Spark (opens in a new tab)](https://weatherspark.com) for detailed data on your city), consider a lead acid system.
# Troubleshooting
> Troubleshooting a Voltaic CORE system. Common root causes, LED indicator codes and diagnosing problems from the dashboard.
## Common Causes If your device stops working or reporting, there are several potential root causes: * Cables are not properly connected. In particular, the output cable needs to be connected for the charge controller to turn on and the battery to charge. * The battery is drained: the power output to the device exceeds the production from the solar panel. This could be from an undersized system, poor panel placement, or extended sub-freezing or overcast conditions. * The solar system is working, but the end device has an issue. * The battery has lost significant capacity. * The solar panel has failed. This is very rare, but possible. We review several common scenarios based on [system indicator lights](#system-indicator-lights) (a technician must be present) and the [dashboard](#using-the-dashboard) using our IoT module. ## System Indicator Lights | Color | Pattern | Meaning | | ----- | ------------- | ------------------------ | | Green | Solid | System on, not charging | | | Flashing slow | Charging | | | Flashing fast | MPPT / fast charging | | Amber | Solid | System on | | | Flashing slow | Low battery voltage | | | Flashing fast | Low voltage protection | | Red | Solid | No output | | | Flashing slow | Over temperature | | | Flashing fast | Short circuit protection | ## Using the Dashboard Our CORE Battery Health Monitor is an optional add-on to any CORE solar system. It reports the following variables to a dashboard: * Solar power to battery (voltage, current, watts) * Load output to device (voltage, current, watts) * Battery temperature * Estimated state of charge (SoC) If you have multiple devices, they can be arranged in a fleet. ### Example 1: Well Sized This is an example of a well performing system. It has a 100 watt solar panel and 60Ah battery powering a 3 Watt continuous load (72 watt hours per day) in Northern California. Each day, the battery charges up fully in a few hours and only loses about 10% of its capacity each day. It could run for about 10 days with no solar input.  ### Example 2: Undersized This system is underpowered. It has a 50 Watt solar panel and 18Ah battery powering a 3.3 Watt continuous load (79 watt hours per day) in the southeastern United States. After an extensive rain period from a hurricane, the battery drained and the output was cut off. In the graph, the green state of charge estimate and the purple load go to zero. After building up a buffer from solar charging, the load turns on again. It repeats this cycle a few times until sunny weather returns. Switching from the 18Ah V102 to the 60Ah V107 would allow the system to get through 9 days of bad weather. Currently, the system can only run for about 2.5 days with no sun before running out of power. Increasing the solar panel from 50 watt to 100 watt would help as well.  ### Example 3: Cold Temperature Dropout This shows the solar panel performance in Toronto, Canada during December. We see the panel voltage peak to about 20V consistently every day, but only 2 of 7 days show any solar charging. In this instance, the temperature is below freezing and the battery is not accepting any charge.  ### Other Identifiable Issues from the Dashboard * **Panel pointed in the wrong direction:** power production will be biased towards morning or evening. * **Panel shaded by buildings or trees:** power production will show cutoffs during the day or lower values than expected. Often paired with a mapping tool. * **Device needs a reboot:** the battery is full and shows high voltage, but zero output.
# Custom Solar Panels
> Voltaic designs custom solar panels when a standard panel doesn't fit, with a custom shape, materials and charge circuit advice.
Voltaic designs and manufactures custom solar panels for high volume applications. Material stack, form factor, power, voltage and wire can be adjusted to meet design requirements. To start a custom project, see [custom solar panels (opens in a new tab)](https://voltaicsystems.com/custom-solar-panels/) on our website.
# Specifications
> Every standard Voltaic solar panel in one table, with nominal electrical specs, size, weight, mounting, connection, and drawing and STEP downloads.
Voltaic designs small solar panels for a wide range of outdoor industrial applications. There are two primary construction techniques for our standard panel line. **ETFE panels** are light, thin and waterproof and are often embedded into a hardware device or enclosure. They range in power from 0.3 to 20 watts and come in 2, 4, 6 and 18 volt versions. **Glass panels** have a glass top-sheet and aluminum frame and come in 25, 50 and 100 watt sizes, all at 18 volts. These are used in our [CORE Solar Systems](/core/). ## Standard Panel Table | SKU | Drawing | 3D model | Construction | Wp (W) | Voc (V) | Isc (A) | Vp (V) | Ip (A) | Cell efficiency | Dimensions (mm) | Weight (g) | Suggested mounting | Connection | | ------------------------------------------------------------------------------------------------------ | ---------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------- | -------------- | ------ | ------- | ------- | ------ | ------ | --------------- | --------------- | ---------- | ------------------ | --------------------------- | | [P122 product page (opens in a new tab)](https://voltaicsystems.com/0-3-watt-6-volt-solar-panel-etfe/) | [P122 R2A technical drawing, PDF (opens in a new tab)](/cad/P122_R2A_voltaic_drawing.pdf "P122 R2A technical drawing (PDF)") | [P122 R2A 3D model, STEP (downloads)](/cad/P122_R2A_voltaic_3d.step "P122 R2A 3D model (STEP)") | ETFE | 0.41 | 7.3 | 0.069 | 6.2 | 0.065 | 24.4% | 52 × 52 | 8 | VHB tape | Solder pads | | [P121 product page (opens in a new tab)](https://voltaicsystems.com/P121/) | [P121 R2A technical drawing, PDF (opens in a new tab)](/cad/P121_R2A_voltaic_drawing.pdf "P121 R2A technical drawing (PDF)") | [P121 R2A 3D model, STEP (downloads)](/cad/P121_R2A_voltaic_3d.step "P121 R2A 3D model (STEP)") | ETFE | 0.43 | 2.9 | 0.18 | 2.5 | 0.17 | 24.4% | 52 × 52 | 8 | VHB tape | Solder pads | | [P134 product page (opens in a new tab)](https://voltaicsystems.com/p134/) | [P134 R2A technical drawing, PDF (opens in a new tab)](/cad/P134_R2A_voltaic_drawing.pdf "P134 R2A technical drawing (PDF)") | [P134 R2A 3D model, STEP (downloads)](/cad/P134_R2A_voltaic_3d.step "P134 R2A 3D model (STEP)") | ETFE | 0.65 | 3.0 | 0.26 | 2.6 | 0.25 | 27.0% | 94 × 32.5 | 12 | VHB tape | Solder pads | | [P123 product page (opens in a new tab)](https://voltaicsystems.com/0-6-watt-6-volt-solar-panel-etfe/) | [P123 R2B technical drawing, PDF (opens in a new tab)](/cad/P123_R2B_voltaic_drawing.pdf "P123 R2B technical drawing (PDF)") | [P123 R2B 3D model, STEP (downloads)](/cad/P123_R2B_voltaic_3d.step "P123 R2B 3D model (STEP)") | ETFE | 0.71 | 7.3 | 0.12 | 6.2 | 0.11 | 24.4% | 66 × 66 | 14 | VHB tape | Solder pads | | [P140 product page (opens in a new tab)](https://voltaicsystems.com/P140/) | [P140 R1A technical drawing, PDF (opens in a new tab)](/cad/P140_R1A_voltaic_drawing.pdf "P140 R1A technical drawing (PDF)") | [P140 R1A 3D model, STEP (downloads)](/cad/P140_R1A_voltaic_3d.step "P140 R1A 3D model (STEP)") | ETFE | 0.72 | 5.8 | 0.15 | 5.0 | 0.14 | 24.4% | 66 × 66 | 14 | VHB tape | Solder pads | | [P138 product page (opens in a new tab)](https://voltaicsystems.com/p138/) | [P138 R1A technical drawing, PDF (opens in a new tab)](/cad/P138_R1A_voltaic_drawing.pdf "P138 R1A technical drawing (PDF)") | [P138 R1A 3D model, STEP (downloads)](/cad/P138_R1A_voltaic_3d.step "P138 R1A 3D model (STEP)") | ETFE | 1.1 | 2.8 | 0.49 | 2.4 | 0.47 | 23.2% | 113 × 66 | 32 | VHB tape | Solder pads | | [P144 product page (opens in a new tab)](https://voltaicsystems.com/P144/) | [P144 R1B technical drawing, PDF (opens in a new tab)](/cad/P144_R1B_voltaic_drawing.pdf "P144 R1B technical drawing (PDF)") | [P144 R1B 3D model, STEP (downloads)](/cad/P144_R1B_voltaic_3d.step "P144 R1B 3D model (STEP)") | Glass laminate | 1.3 | 7.2 | 0.22 | 6.1 | 0.21 | 23.5% | 113 × 66 | 32 | VHB tape | Solder pads | | [P124 product page (opens in a new tab)](https://voltaicsystems.com/1-watt-6-volt-solar-panel-etfe/) | [P124 R4G technical drawing, PDF (opens in a new tab)](/cad/P124_R4G_voltaic_drawing.pdf "P124 R4G technical drawing (PDF)") | [P124 R4G 3D model, STEP (downloads)](/cad/P124_R4G_voltaic_3d.step "P124 R4G 3D model (STEP)") | ETFE | 1.4 | 7.3 | 0.23 | 6.2 | 0.22 | 24.4% | 113 × 66 | 32 | VHB tape | Solder pads | | [P126 product page (opens in a new tab)](https://voltaicsystems.com/P126/) | [P126 R3C technical drawing, PDF (opens in a new tab)](/cad/P126_R3C_voltaic_drawing.pdf "P126 R3C technical drawing (PDF)") | [P126 R3C 3D model, STEP (downloads)](/cad/P126_R3C_voltaic_3d.step "P126 R3C 3D model (STEP)") | ETFE | 2.6 | 8.7 | 0.37 | 7.5 | 0.35 | 24.4% | 136 × 112 | 79 | VHB tape | Cable with 3.5 × 1.1mm plug | | [P139 product page (opens in a new tab)](https://voltaicsystems.com/p139/) | [P139 R1A technical drawing, PDF (opens in a new tab)](/cad/P139_R1A_voltaic_drawing.pdf "P139 R1A technical drawing (PDF)") | [P139 R1A 3D model, STEP (downloads)](/cad/P139_R1A_voltaic_3d.step "P139 R1A 3D model (STEP)") | ETFE | 2.7 | 2.8 | 1.19 | 2.4 | 1.14 | 23.2% | 136 × 112 | 79 | VHB tape | Solder pads | | [P105 product page (opens in a new tab)](https://voltaicsystems.com/5-watt-panel-etfe/) | [P105 R9C technical drawing, PDF (opens in a new tab)](/cad/P105_R9C_voltaic_drawing.pdf "P105 R9C technical drawing (PDF)") | [P105 R9C 3D model, STEP (downloads)](/cad/P105_R9C_voltaic_3d.step "P105 R9C 3D model (STEP)") | ETFE | 5.9 | 7.3 | 1.00 | 6.2 | 0.95 | 24.4% | 223 × 148 | 188 | Through-holes | Cable with 3.5 × 1.1mm plug | | [P108 product page (opens in a new tab)](https://voltaicsystems.com/9-watt-18v-panel-etfe/) | [P108 R7A technical drawing, PDF (opens in a new tab)](/cad/P108_R7A_voltaic_drawing.pdf "P108 R7A technical drawing (PDF)") | [P108 R7A 3D model, STEP (downloads)](/cad/P108_R7A_voltaic_3d.step "P108 R7A 3D model (STEP)") | ETFE | 9.3 | 22.1 | 0.51 | 19.2 | 0.48 | 23.2% | 273.5 × 223 | 328 | Through-holes | Cable with 3.5 × 1.1mm plug | | [P110 product page (opens in a new tab)](https://voltaicsystems.com/10-watt-panel-etfe/) | [P110 R7C technical drawing, PDF (opens in a new tab)](/cad/P110_R7C_voltaic_drawing.pdf "P110 R7C technical drawing (PDF)") | [P110 R7C 3D model, STEP (downloads)](/cad/P110_R7C_voltaic_3d.step "P110 R7C 3D model (STEP)") | ETFE | 11.8 | 7.3 | 1.99 | 6.2 | 1.89 | 24.4% | 273.5 × 223 | 328 | Through-holes | Cable with 3.5 × 1.1mm plug | | [P120 product page (opens in a new tab)](https://voltaicsystems.com/20-watt-6-volt-solar-panel-etfe/) | [P120 R3C technical drawing, PDF (opens in a new tab)](/cad/P120_R3C_voltaic_drawing.pdf "P120 R3C technical drawing (PDF)") | [P120 R3C 3D model, STEP (downloads)](/cad/P120_R3C_voltaic_3d.step "P120 R3C 3D model (STEP)") | ETFE | 24.7 | 7.3 | 4.17 | 6.2 | 3.96 | 24.4% | 436 × 274 | 709 | Through-holes | Cable with 3.5 × 1.1mm plug | | [P152 product page (opens in a new tab)](https://voltaicsystems.com/P152/) | [P152 R6A technical drawing, PDF (opens in a new tab)](/cad/P152_R6A_voltaic_drawing.pdf "P152 R6A technical drawing (PDF)") | [P152 R6A 3D model, STEP (downloads)](/cad/P152_R6A_voltaic_3d.step "P152 R6A 3D model (STEP)") | Glass laminate | 28.7 | 20.7 | 1.67 | 18.0 | 1.60 | 23.2% | 507 × 307 | 2,000 | Z-clamps | MC4 connectors | | [P150 product page (opens in a new tab)](https://voltaicsystems.com/P150/) | [P150 R5A technical drawing, PDF (opens in a new tab)](/cad/P150_R5A_voltaic_drawing.pdf "P150 R5A technical drawing (PDF)") | [P150 R5A 3D model, STEP (downloads)](/cad/P150_R5A_voltaic_3d.step "P150 R5A 3D model (STEP)") | Glass laminate | 57.8 | 20.7 | 3.37 | 18.0 | 3.21 | 23.2% | 586 × 507 | 3,400 | Z-clamps | MC4 connectors | | [P151 product page (opens in a new tab)](https://voltaicsystems.com/P151/) | [P151 R6A technical drawing, PDF (opens in a new tab)](/cad/P151_R6A_voltaic_drawing.pdf "P151 R6A technical drawing (PDF)") | [P151 R6A 3D model, STEP (downloads)](/cad/P151_R6A_voltaic_3d.step "P151 R6A 3D model (STEP)") | Glass laminate | 115.5 | 20.7 | 6.73 | 18.0 | 6.43 | 23.2% | 980 × 586 | 6,800 | Z-clamps | MC4 connectors | Electrical values are nominal: the rated values at [Standard Test Conditions](#standard-test-conditions). Output in the field is lower. For full performance details see each panel’s technical datasheet. ## Standard Test Conditions Panel electrical ratings (Voc, Isc, Vp, Ip and Wp) are measured at Standard Test Conditions (STC), the reference conditions used by [IEC 61215](/panels/testing-and-qualification/#standards-referenced) and every panel datasheet: * Irradiance of 1,000W/m² * AM1.5 spectrum (sunlight through 1.5 atmospheres, the reference for mid-latitudes) * Cell temperature of 25°C * Light perpendicular to the panel A deployed panel rarely meets all four at once. Irradiance is usually lower, the cells run hotter or cooler than 25°C, and the panel seldom points straight at the sun. Expect less than the rated power, and use [Estimating Power Production](#estimating-power-production) to size for a real deployment. ## Estimating Power Production The expected peak power from the solar panel is listed in each technical drawing. This is the power produced at [Standard Test Conditions](#standard-test-conditions): We use the [PVGIS](#tools) tool to estimate the available energy and [shademap.app](#tools) to estimate the effect of shading by buildings or trees. To estimate usable energy, you also need to discount this value by your: 1. Circuit efficiency 2. Energy lost into your storage element ### Tools We use two free tools to estimate available energy on a solar panel and potential shading impacts. * [PVGIS (opens in a new tab)](https://re.jrc.ec.europa.eu/pvg_tools/en/) gives the daily energy a panel produces at a location for a given angle and azimuth, by month. Size for the worst months, which are December and January in the northern hemisphere. The Voltaic blog has a [step-by-step guide to PVGIS for IoT devices (opens in a new tab)](https://blog.voltaicsystems.com/estimate-solar-irradiance-iot-device/). * [shademap.app (opens in a new tab)](https://shademap.app) shows how many hours of direct sun a spot receives on a given date, so you can discount the PVGIS figure for trees and buildings and compare alternative spots. ### Panel Angle The panel angle affects how much energy the solar panel generates during different times of the year. This choice also has different physical design implications. | Position | Advantages | Disadvantages | | --------------- | ----------------------------------------------------------------- | ---------------------------------------------------------------- | | Vertical (90°) | No snow buildup; limits biofouling; takes little horizontal space | Lower power if not facing south; low power in summer | | Horizontal (0°) | Works in any device orientation | Low power in winter; most exposed to snow buildup and biofouling | | Angled 30–70° | Highest power when facing south | Must be pointed the right way; sticks out from the enclosure | ### Example 1: Fixed Unshaded Agricultural Gateway Assume you are considering the 2.6W [P126 (opens in a new tab)](https://voltaicsystems.com/P126/) for a low-power gateway in an agricultural application. The panel will be pointed South with no obstructions. You are considering placing the panel flat on top of the enclosure, at a 60° angle or vertical. You believe most of your customers will be in the central United States, between Texas and North Dakota. From the technical drawing, the P126 has an expected peak power of 2.21W. Using [PVGIS](#tools), you can evaluate the energy generated per day at the summer and winter solstices in Dallas, Texas (southern US) and Bismarck, North Dakota (northern US) in the three positions. **Average energy per day from a south-facing P126 (Wh)** | Site | Vertical | | Horizontal | | Angled 60° | | | ------------ | -------- | -------- | ---------- | -------- | ---------- | -------- | | | June | December | June | December | June | December | | Dallas, TX | 2.7 | 6.2 | 10.1 | 3.9 | 6.3 | 7.0 | | Bismarck, ND | 4.4 | 5.1 | 10.4 | 2.1 | 5.2 | 5.2 | This table shows the average energy the panel can produce per day if it is held at its maximum power point. The angled panel provides the most consistent energy across locations and seasons. The horizontal panel performs worst in Bismarck in winter, and the vertical panel performs worst in Dallas in June. The energy available to your device will be slightly lower, because: * most low-power solar circuits don’t have perfect maximum power point tracking; a buck converter is typically about 90% efficient * energy is lost as power goes from electrical to chemical energy in your storage element. ### Example 2: Fixed Partially Shaded Air Quality Monitor Assume you are placing the 5.9W [P105 (opens in a new tab)](https://voltaicsystems.com/5-watt-panel-etfe/) in Sheep Meadow, Central Park, to power an air quality monitoring station. The approved location is in the southeast corner, and it looks sunny when you visit on a June afternoon. The technical drawing shows an expected peak power of 4.96W, and the panel sits at 45° on the [BK102 bracket](/brackets/). According to [PVGIS](#tools), the panel could produce an average of 11.9Wh per day in December.  On [shademap.app](#tools), you look at the expected shadows from trees in December. This is when the sun is at its lowest and you see significant shadows from the trees in the southeast corner.  In December, nearby rooftops get 9 hours of sunlight per day. The southeast corner of the meadow gets 4 hours (light green) and the northeast corner closer to 7 (green and red). Moving the station to the northeast corner will increase the energy the panel produces. Either way, it will be less than the 11.9Wh estimated by PVGIS. The actual number is hard to estimate exactly, but is likely to be 40 to 70% of that value depending on the location.  ### Example 3: Varying Orientation Livestock Tracker Assume you are evaluating the 0.7W [P123 (opens in a new tab)](https://voltaicsystems.com/0-6-watt-6-volt-solar-panel-etfe/) for a tracking application. It will be placed on the side of a vehicle (vertical) or on the ear of a cow, and could be facing in any direction as it moves through the day. From the technical drawing, the expected peak power at [Standard Test Conditions](#standard-test-conditions) is 0.60W. If the vehicle moves throughout the country, you can get a baseline by averaging the energy facing each direction. **Average energy per day from a vertical P123 in Omaha, Nebraska in December, mixed orientation (Wh)** | South | East | West | North | Average | | ----- | ---- | ---- | ----- | ------- | | 0.82 | 0.28 | 0.28 | 0.07 | 0.36 | At scale, testing from a pilot will give more exact numbers. Until then, 0.36Wh per day from a 0.6W panel mounted vertically on a rotating object is a good baseline for the maximum daily energy available before it enters the circuit. ## Solar Panel Cleaning The ETFE top layer on most Voltaic solar panels has very low surface energy, which keeps most debris from building up on the panel. If dust does build up on the panel, we observe power losses of about 10%. At small scale, clean panels with isopropyl alcohol or soapy water. Customers regularly clean vehicles with Voltaic solar panels mounted on them using pressure washers.
# Mounting
> Mounting Voltaic solar panels and CORE systems. VHB tape for small ETFE panels, and drawings, 3D models and assembly instructions for the BK101, BK102, BK103, BK108, BK110 and BK111 brackets.
## VHB Tape For small ETFE panels (0.3 to 2W), VHB (Very High Bond) tape from 3M is the most common way customers attach panels to enclosures, including in high speed asset tracking applications. Applied correctly, it provides a waterproof and secure connection. | VHB Gasket | Compatible panels | | ------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------- | | [G105 (opens in a new tab)](https://voltaicsystems.com/G105/) | [P121 (opens in a new tab)](https://voltaicsystems.com/P121/), [P122 (opens in a new tab)](https://voltaicsystems.com/0-3-watt-6-volt-solar-panel-etfe/) | | [G106 (opens in a new tab)](https://voltaicsystems.com/G106/) | [P123 (opens in a new tab)](https://voltaicsystems.com/0-6-watt-6-volt-solar-panel-etfe/), [P140 (opens in a new tab)](https://voltaicsystems.com/P140/) | | [G108 (opens in a new tab)](https://voltaicsystems.com/G108/) | [P124 (opens in a new tab)](https://voltaicsystems.com/1-watt-6-volt-solar-panel-etfe/) | | [G110 (opens in a new tab)](https://voltaicsystems.com/G110/) | [P126 (opens in a new tab)](https://voltaicsystems.com/P126/) | | [G124 (opens in a new tab)](https://voltaicsystems.com/g124/) | [P134 (opens in a new tab)](https://voltaicsystems.com/p134/) | ### Recommendations for Using VHB 1. Check with a 3M representative that the tape bonds to your enclosure material. Voltaic uses general purpose 3M 5952 tape, 1.1mm thick. 2. Read 3M’s [application instructions (opens in a new tab)](https://www.3m.com/3M/en_US/vhb-tapes-us/resources/applying-3m-vhb-tapes/) for VHB tapes. 3. Practice on clear acrylic to confirm the tape is fully wetted out and bonded to the panel. 4. Test the panel’s power output before and after installation. We recommend setting the panel edge sub-flush in the enclosure. An impact on the panel edge can damage the lamination and, over time, lead to delamination. ## Brackets Voltaic brackets mount a solar panel to a pole or wall. The BK101, BK102 and BK103 are for Voltaic’s small to medium sized ETFE solar panels and [AxON Solar Systems](/axon/). They hold the panel at a fixed angle. The BK108, BK110 and BK111 are for glass 25, 50 and 100 watt solar panels and the [CORE Solar Systems](/core/). The angles are adjustable and the brackets are designed to mount the CORE batteries. ### Downloads | Bracket | Compatible panels | Drawing | 3D model | Instructions | | --------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------- | -------------------------------------- | ----------------------------------------------------------------------------- | | [BK101 (opens in a new tab)](https://voltaicsystems.com/BK101/) | [P126 (opens in a new tab)](https://voltaicsystems.com/P126/) | [PDF](/cad/BK101_R4_voltaic_drawing.pdf) | [STEP](/cad/BK101_R4_voltaic_3d.step) | | | [BK102 (opens in a new tab)](https://voltaicsystems.com/BK102/) | [P105 (opens in a new tab)](https://voltaicsystems.com/5-watt-panel-etfe/) | [PDF](/cad/BK102_R7D_voltaic_drawing.pdf) | [STEP](/cad/BK102_R7D_voltaic_3d.step) | | | [BK103 (opens in a new tab)](https://voltaicsystems.com/BK103/) | [P110 (opens in a new tab)](https://voltaicsystems.com/10-watt-panel-etfe/), [P108 (opens in a new tab)](https://voltaicsystems.com/9-watt-18v-panel-etfe/), [P120 (opens in a new tab)](https://voltaicsystems.com/20-watt-6-volt-solar-panel-etfe/) | [PDF](/cad/BK103_R9A_voltaic_drawing.pdf) | [STEP](/cad/BK103_R9A_voltaic_3d.step) | | | [BK108 (opens in a new tab)](https://voltaicsystems.com/BK108/) | [P152 (opens in a new tab)](https://voltaicsystems.com/P152/), [P150 (opens in a new tab)](https://voltaicsystems.com/P150/), [P120 (opens in a new tab)](https://voltaicsystems.com/20-watt-6-volt-solar-panel-etfe/) | | | [Assembly instructions (PDF)](/manuals/BK108_assembly_instructions.pdf) | | [BK110 (opens in a new tab)](https://voltaicsystems.com/BK110/) | [P151 (opens in a new tab)](https://voltaicsystems.com/P151/) | | | [Assembly instructions (PDF)](/manuals/BK110_BK111_assembly_instructions.pdf) | | [BK111 (opens in a new tab)](https://voltaicsystems.com/BK111/) | [P151 x 2 (opens in a new tab)](https://voltaicsystems.com/P151/) | | | [Assembly instructions (PDF)](/manuals/BK110_BK111_assembly_instructions.pdf) | The BK110 and BK111 share one set of instructions.
# Testing and Qualification
> Environmental, mechanical, immersion and chemical stress tests on Voltaic ETFE solar panels, the standards they follow, and the ATEX certification.
Voltaic’s standard solar panel stack consists of an ETFE (ethylene tetrafluoroethylene) front sheet, EVA (ethylene-vinyl acetate) encapsulant, the solar cells and a PCB substrate. They are are qualified in the field and in laboratory stress tests to IEC, SAE, MIL-STD and AAR standards. For the conditions or results of a test, [contact us (opens in a new tab)](https://voltaicsystems.com/contact-us/). ## Environmental Tests | Test | Standard | | -------------------------------------- | ------------------------------- | | Accelerated aging (heat, humidity, UV) | IEC 61215 MQT 08 | | Accelerated aging (heat, humidity, UV) | Self-specified | | Damp heat | IEC 61215 MQT 13 | | Humidity freeze | SAE J1455 (2017) 4.2.3, Fig. 4A | | Humidity freeze | Self-specified | | Thermal cycling | IEC 61215 MQT 11 | | Thermal shock | SAE J1455 (2017) 4.1.3.2 | ## Mechanical Tests | Test | Standard | | -------------------- | -------------------------------------- | | Handling drop | SAE J1455 (2017) 4.10.3.1 | | Impact | IEC 62262 IK08 and IK09 | | Mechanical shock | SAE J1455 (2017) 4.10 | | Mechanical shock | MIL-STD-810H Method 516.8, Procedure I | | Random vibration | SAE J1455 (2017) 4.5 | | Random vibration | AAR S-9401 3.2.4.2 and Table 3.3 | | Sinusoidal vibration | SAE J1455 (2017) Appendix A | | Sinusoidal vibration | AAR S-9401 3.2.4.1 and Table 3.3 | ## Immersion and Exposure Tests | Test | Standard | | ------------------------------ | --------------------------------------------------------- | | Chemicals and oils | SAE J1455 (2017) 4.4.3.2 | | Dust and sand (IP6X) | IEC 60529 (2001) 13.4 and 13.6.2 | | Ingress, immersion (IPX7) | IEC 60529 (2001) 14.2.7; ISO 20653 (2013) Table 7, Fig. 7 | | Ingress, pressure wash (IPX9K) | IEC 60529 | | Salt spray (fog) | SAE J1455 (2017) 4.3.3.1 (refers to ASTM B117) | | Salt water immersion | SAE J1455 (2017) 4.3.3.2 | | Water immersion | Self-specified | ## ATEX Certification ATEX is the EU framework for equipment used in potentially explosive atmospheres. Voltaic’s SMT (surface-mount) ETFE panels have been integrated into devices that have passed two ATEX testing standards: | Atmosphere | Marking | | ---------- | -------------------------- | | Gas | II 2G Ex ib IIB T4 Gb | | Dust | II 2D Ex ib IIIB T135°C Db | ## Standards Referenced Tests marked “Self-specified” follow Voltaic’s own profile. The other tests follow these standards: | Standard | What it covers | | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | | [AAR S-9401 (opens in a new tab)](https://www.aar.com/standards/) | The Association of American Railroads’ environmental requirements for railroad electronics, part of its Manual of Standards and Recommended Practices. It sets the conditions, including vibration, that electronics on rail equipment must withstand. | | [ASTM B117 (opens in a new tab)](https://store.astm.org/b0117-26.html) | The standard practice for running a salt spray (fog) test: a controlled 5% salt fog used to compare corrosion resistance. The product specification sets how long the exposure lasts. | | [ATEX (Directive 2014/34/EU) (opens in a new tab)](https://single-market-economy.ec.europa.eu/single-market/european-standards/harmonised-standards/equipment-explosive-atmospheres-atex_en) | The EU directive for equipment and protective systems used in potentially explosive atmospheres, in force since 20 April 2016. See [ATEX Certification](#atex-certification) above. | | [IEC 60529 (opens in a new tab)](https://webstore.iec.ch/en/publication/2452) | The IP code, which rates an enclosure’s protection against solid objects and dust (first digit) and against water (second digit). For example, IP6X is dust-tight and IPX7 survives temporary immersion. | | [IEC 61215 (opens in a new tab)](https://webstore.iec.ch/en/publication/61345) | The international standard for design qualification and type approval of solar (PV) modules for long-term outdoor use. Its individual tests are numbered as module quality tests (MQT), such as MQT 11 for thermal cycling and MQT 13 for damp heat. | | [IEC 62262 (opens in a new tab)](https://webstore.iec.ch/en/publication/71109) | The IK code, which rates an enclosure’s protection against mechanical impact, from IK00 (no protection) to IK10 (20J). | | [ISO 20653 (opens in a new tab)](https://www.iso.org/standard/76116.html) | The IP code for electrical equipment on road vehicles. It adds “K” ratings such as IPX9K: a high-pressure jet of hot water at about 80°C. | | [MIL-STD-810H (opens in a new tab)](https://quicksearch.dla.mil/qsDocDetails.aspx?ident_number=35978) | The US Department of Defense’s standard for environmental engineering and laboratory tests. Method 516.8 covers mechanical shock during handling, transport and use. | | [SAE J1455 (opens in a new tab)](https://saemobilus.sae.org/content/j1455_201703) | SAE’s recommended environmental practices for designing electronics for heavy-duty vehicles: on- and off-road trucks, trailers, buses, and construction and agricultural equipment. It covers the climatic, mechanical and electrical conditions the electronics must survive. |
# For AI Tools & Developers
> How AI assistants and software can read Voltaic's technical documentation. llms.txt, a JSON product specification API and crawler policy.
## Machine-readable entry points | URL | What it is | | ------------------------------------------ | ------------------------------------------------------------------------------------------------------------------ | | [`/llms.txt`](/llms.txt) | Index of the whole site for large language models ([llmstxt.org (opens in a new tab)](https://llmstxt.org) format) | | [`/llms-full.txt`](/llms-full.txt) | Every page as clean Markdown in one file | | [`/llms-small.txt`](/llms-small.txt) | A compact version for small context windows | | [`/specs.json`](/specs.json) | Every product’s specifications as JSON | | `/specs/{id}.json` | One product, e.g. [`/specs/p105.json`](/specs/p105.json) | | [`/sitemap-index.xml`](/sitemap-index.xml) | Every page, for crawlers | ## Using the specs API * curl
```bash
# One product by its id, here the P105. For every product, request /specs.json instead.
curl -s https://docs.voltaicsystems.com/specs/p105.json
```
* Python
```python
import requests
specs = requests.get("https://docs.voltaicsystems.com/specs.json").json()
six_volt = [
p for p in specs["products"]
if p["family"] == "Standard Solar Panel" and round(p["electrical"]["vmp"]) == 6
]
for p in sorted(six_volt, key=lambda p: p["electrical"]["pmax"]):
print(p["id"], p["electrical"]["pmax"], "W", p["url"])
```
* JavaScript
```js
const res = await fetch('https://docs.voltaicsystems.com/specs.json');
const { products } = await res.json();
const core = products.filter((p) => p.family === 'Voltaic CORE');
console.table(core.map((p) => ({ id: p.id, summary: p.summary })));
```
## Crawler policy All crawlers are welcome, including AI search and assistant crawlers (ClaudeBot, Claude-SearchBot, Claude-User, GPTBot, OAI-SearchBot, ChatGPT-User, PerplexityBot). See [`/robots.txt`](/robots.txt).
# Specifications
> Voltaic USB battery packs for solar-powered devices. Specifications, downloads, storage and safety for the V25, V50 and V75 aluminium-body packs.
The [V25 (opens in a new tab)](https://voltaicsystems.com/v25/), [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) and [V75 (opens in a new tab)](https://voltaicsystems.com/v75) are Voltaic’s USB battery packs. They all have an aluminium-body, Li-ion NMC cells and two always-on USB-A outputs. They charge well from solar panels or any 5 volt USB source and can charge and discharge simultaneously. The batteries are used in a range of applications that require an un-interrupted 5 volt power supply: microcontrollers, time-lapse cameras, monitoring equipment. For the same battery packs in a waterproof housing for outdoor IoT deployments, see [AxON](/axon/). Values are nominal. The USB-C PD port is the top port; the Always On outputs are the two USB-A ports. See [Always On](/usb-battery-packs/instructions/#always-on) for how the ports behave. | Specification | V25 | V50 | V75 | | ----------------------------- | ------------------------------------------------ | ------------------ | ------------------ | | Battery | | | | | Chemistry | Li-ion | | | | Capacity | 6,700mAh | 13,400mAh | 20,100mAh | | Energy | 24Wh | 48Wh | 72Wh | | Outputs | | | | | USB-A (×2), Always On | 5V / 2A each, 3A total | | | | USB-C PD, top port (in / out) | 5V / 3.6A, 9V / 2.2A, 12V / 1.6ANot Always On | | | | Always On consumption | 7mA (26mW)With a USB-A cable connected | | | | Inputs | | | | | USB-C solar input | 5 to 6V / 2A | | | | 3.5 × 1.1mm solar input | 5 to 6V / 2A | | | | Maximum power point | 5.2V | | | | Minimum charge current | 5mAIndicators turn on at 60mA | | | | USB-C input only | — | — | 5V / 2A | | Protection | | | | | Electrical | Short circuit, over charge, over discharge | | | | Over temperature | 45°C input cutoff, 60°C output cutoff | | | | Under temperature | 0°C input cutoff, −15°C output cutoff | | | | Physical | | | | | Dimensions | 8 × 8.2 × 2.4cm | 11.8 × 8.2 × 2.4cm | 15.5 × 8.2 × 2.4cm | | Mass | 262g | 368g | 502g | | Compliance | | | | | Transport | UN38.3Safe for air travel, carry-on luggage only | | | | Safety standards | IEC 62133, IEC 62368-1 | | | | Markings | CE, FCC, RoHS | | | ## Downloads | Pack | 3D model | Instructions | | ----------------------------------------------------------- | ---------------------------------- | -------------------------------------------------------------------------- | | [V25 (opens in a new tab)](https://voltaicsystems.com/v25/) | [STEP](/cad/V25-AL_voltaic_3d.stp) | [Instruction booklet (PDF)](/manuals/V25_V50_V75_AL_instructions_2025.pdf) | | [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) | [STEP](/cad/V50-AL_voltaic_3d.stp) | [Instruction booklet (PDF)](/manuals/V25_V50_V75_AL_instructions_2025.pdf) | | [V75 (opens in a new tab)](https://voltaicsystems.com/v75) | [STEP](/cad/V75-AL_voltaic_3d.stp) | [Instruction booklet (PDF)](/manuals/V25_V50_V75_AL_instructions_2025.pdf) | One booklet covers all three packs. The [Instructions](/usb-battery-packs/instructions/) page has the same content on the web. If a pack or device stops working, see [Troubleshooting](/usb-battery-packs/troubleshooting/). ## Storage and Disposal If you aren’t using the pack, disconnect all cables and store it somewhere dry between 20 and 35°C. With an output cable connected, the pack stays on and drains completely, which can damage the cells. Check the charge level every 6 months. The pack contains lithium-ion cells, so don’t put it in the trash. Take it to a local battery or e-waste recycler. ## Safety Precautions Caution * Do not expose the pack to high heat or open flame. * Dispose of the pack properly. Do not throw it in the trash or incinerate it. * Do not get the pack wet, store it in high humidity or short-circuit it. * Do not open or tamper with the pack. * Do not connect packs in parallel. ## Certificates The V25, V50 and V75 carry these marks and certifications: * CE * FCC * [RoHS (opens in a new tab)](https://environment.ec.europa.eu/topics/waste-and-recycling/rohs-directive_en) * [IEC 62133 (opens in a new tab)](https://webstore.iec.ch/en/publication/32662), safety of portable lithium cells and batteries * [IEC 62368-1 (opens in a new tab)](https://webstore.iec.ch/en/publication/69308), safety of audio, video and information technology equipment The safety data sheet (MSDS), [UN38.3 (opens in a new tab)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) test summary and IEC test reports are available on request.
# Instructions
> Instructions for the Voltaic V25, V50 and V75 USB battery packs: ports, charging a device, recharging the pack, the charge level indicator, charge times and temperature limits. Includes the instruction booklet (PDF).
Plug your device into either USB-A Always On output or the top USB-C PD port, and recharge the pack from any USB port or a Voltaic 5 to 7V solar panel. The pack charges your device while it recharges. The [V25 (opens in a new tab)](https://voltaicsystems.com/v25/), [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) and [V75 (opens in a new tab)](https://voltaicsystems.com/v75) charge most USB devices, including phones, tablets, cameras and microcontrollers. This page has the same content as the booklet that ships with the pack. To print it or keep a copy, download the [instruction booklet (PDF)](/manuals/V25_V50_V75_AL_instructions_2025.pdf). Caution The inside of a solar charger case can become hot in the sun. In hot conditions, open the battery compartment to let air through and avoid overheating. ## Product Details  1. Charge Level Button 2. Charge level indicator 3. USB-C solar input 4. 3.5 × 1.1mm DC solar input 5. USB-C PD input and output 6. USB-A Always On output 7. USB-A Always On output 8. USB-C charging cable ## Charging a Device Plug your device’s USB charging cable into either USB-A port, or use a USB-C cable in the top USB-C PD port. Your device starts charging by itself. The two USB-A ports are Always On; see [Always On](#always-on). Unplug cables from the outputs when you store the pack. ## Always On The two USB-A ports are the designated 5V Always On output ports. The ports are turned on by connecting a USB-A cable. The cable completes a switch and activates the output. The USB-C PD port should not be used for power output or input when using Always On. The USB-A output will not shut off even if your device is drawing low or no power. To stop charging your device, double-tap the Charge Level Button or disconnect the cable from the battery. To resume charging, tap the Charge Level Button once. The battery recovers into Always On mode after discharge, over-temperature and under-temperature events. Power consumption in Always On mode is approximately 7mA (26mW). ## Recharging the Pack  Recharge the pack from a Voltaic 5 to 7V [solar panel](/panels/), or from any USB port with the included USB-C charging cable. You can also recharge through the top USB-C PD port with a USB-C to USB-C cable, which isn’t included. If you use Always On, recharge from the side USB-C port or the 3.5 × 1.1mm DC solar input instead. ## Charge Level Indicator Press the Charge Level Button to show the charge level. While the pack recharges, the LEDs blink to show progress.  ## Charge Times Charge times are in hours, from empty to full. Solar times assume full sun on the panel. | Power source | [V25 (opens in a new tab)](https://voltaicsystems.com/v25/) | [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) | [V75 (opens in a new tab)](https://voltaicsystems.com/v75) | | --------------- | ----------------------------------------------------------- | ----------------------------------------------------------- | ---------------------------------------------------------- | | USB (5V) | 2.5 | 5.0 | 7.5 | | USB-C PD (20W) | 1.5 | 3.0 | 4.5 | | 5W solar panel | 6.0 | 12.0 | 18.0 | | 10W solar panel | 3.0 | 6.0 | 9.0 | ## Fastest Solar Charging 1. Put the solar panel outside in direct sunlight. Charging takes longer on cloudy days. 2. Point the panel straight at the sun and keep it out of shade. 3. Check that the LEDs on the pack light up in sequence. ## Specifications Capacity, port ratings, protections and dimensions for each pack are in the [specifications table](/usb-battery-packs/). ## Storage and Safety Fully discharge and recharge the pack every 5 months to preserve battery life, and keep it within these temperatures: | Activity | Temperature range | | -------------------- | ------------------------ | | Storing the pack | 20 to 35°C (68 to 95°F) | | Charging the pack | 0 to 45°C (32 to 113°F) | | Discharging the pack | −15 to 55°C (5 to 131°F) | Caution * Do not expose the pack to high heat or open flame. * Dispose of the pack properly. Do not throw it in the trash or incinerate it. * Do not get the pack wet, store it in high humidity or short-circuit it. * Do not open or tamper with the pack. * Do not connect packs in parallel.
# System Monitoring
> Monitoring Voltaic V25, V50 and V75 USB battery packs. Reading the battery level from the analog voltage on the USB-C PD port's SBU pins.
## Reading the Battery Level The top USB-C Power Delivery (PD) port of the [V25 (opens in a new tab)](https://voltaicsystems.com/v25/), [V50 (opens in a new tab)](https://voltaicsystems.com/V50/) and [V75 (opens in a new tab)](https://voltaicsystems.com/v75) carries an analog voltage on its sideband use (SBU) pins that tracks the cell voltage, so you can read it to estimate the remaining capacity. The blog post [Updated USB-C PD and Always On for V25, V50 and V75 Batteries (opens in a new tab)](https://blog.voltaicsystems.com/updated-usb-c-pd-and-always-on-for-v25-v50-v75-batteries/) has the details.
# Troubleshooting
> Troubleshooting the Voltaic V25, V50 and V75 USB battery packs: checking the charge, a device that doesn't charge, a pack that doesn't recharge and fault lights.
If a device doesn’t power up, first find out whether the problem is the pack, the cables or the device. Work through the checks below in order. ## Checking the Charge Disconnect all cables and press the Charge Level Button. Between 1 and 4 LEDs light up solid, then turn off. * If no LEDs light up, the pack is probably fully discharged. Recharge it. * If the LEDs flash, see [Fault Indication](#fault-indication). ## Device Not Charging If the pack has charge but doesn’t charge your device: * For Always On, check that the device is on a USB-A port, not the USB-C PD port. * Try a different cable. * Press the Charge Level Button. A double-tap switches the output off so the pack can be stored with a cable connected, and it may have been switched off that way. ## Pack Not Recharging Connect a USB-C power cable to either USB-C port. The LEDs show 4 solid lights when the pack is full, or blink in sequence while it recharges. If nothing happens: * Recharge from the other USB-C port. * Try a different cable and charger. The cable or charger may be faulty, or a charger may not be compatible with the charging port. ## Fault Indication If all 4 LEDs flash several times, there may be a fault. Disconnect all cables to find out whether the fault is inside the pack or in a connected cable or device.