Skip to content

Troubleshooting

If your device stops working or reporting, there are several potential root causes:

  • Cables are not properly connected. In particular, the output cable needs to be connected for the charge controller to turn on and the battery to charge.
  • The battery is drained: the power output to the device exceeds the production from the solar panel. This could be from an undersized system, poor panel placement, or extended sub-freezing or overcast conditions.
  • The solar system is working, but the end device has an issue.
  • The battery has lost significant capacity.
  • The solar panel has failed. This is very rare, but possible.

We review several common scenarios based on system indicator lights (a technician must be present) and the dashboard using our IoT module.

ColorPatternMeaning
GreenSolidSystem on, not charging
Flashing slowCharging
Flashing fastMPPT / fast charging
AmberSolidSystem on
Flashing slowLow battery voltage
Flashing fastLow voltage protection
RedSolidNo output
Flashing slowOver temperature
Flashing fastShort circuit protection

Our CORE Battery Health Monitor is an optional add-on to any CORE solar system. It reports the following variables to a dashboard:

  • Solar power to battery (voltage, current, watts)
  • Load output to device (voltage, current, watts)
  • Battery temperature
  • Estimated state of charge (SoC)

If you have multiple devices, they can be arranged in a fleet.

This is an example of a well performing system. It has a 100 watt solar panel and 60Ah battery powering a 3 Watt continuous load (72 watt hours per day) in Northern California.

Each day, the battery charges up fully in a few hours and only loses about 10% of its capacity each day. It could run for about 10 days with no solar input.

Dashboard chart over seven days: battery stays between 90 and 100%, panel power peaks near 70W each midday, load power is a steady few watts

This system is underpowered. It has a 50 Watt solar panel and 18Ah battery powering a 3.3 Watt continuous load (79 watt hours per day) in the southeastern United States. After an extensive rain period from a hurricane, the battery drained and the output was cut off.

In the graph, the green state of charge estimate and the purple load go to zero. After building up a buffer from solar charging, the load turns on again. It repeats this cycle a few times until sunny weather returns.

Switching from the 18Ah V102 to the 60Ah V107 would allow the system to get through 9 days of bad weather. Currently, the system can only run for about 2.5 days with no sun before running out of power.

Increasing the solar panel from 50 watt to 100 watt would help as well.

Dashboard chart over eight days: battery falls to 0% and load power drops to zero several times, then recovers as panel power returns

This shows the solar panel performance in Toronto, Canada during December.

We see the panel voltage peak to about 20V consistently every day, but only 2 of 7 days show any solar charging. In this instance, the temperature is below freezing and the battery is not accepting any charge.

Dashboard chart over seven December days: panel voltage reaches about 20V every day, but panel current and power appear on only two days

Other Identifiable Issues from the Dashboard

Section titled “Other Identifiable Issues from the Dashboard”
  • Panel pointed in the wrong direction: power production will be biased towards morning or evening.
  • Panel shaded by buildings or trees: power production will show cutoffs during the day or lower values than expected. Often paired with a mapping tool.
  • Device needs a reboot: the battery is full and shows high voltage, but zero output.