Troubleshooting
Common Causes
Section titled “Common Causes”If your device stops working or reporting, there are several potential root causes:
- Cables are not properly connected. In particular, the output cable needs to be connected for the charge controller to turn on and the battery to charge.
- The battery is drained: the power output to the device exceeds the production from the solar panel. This could be from an undersized system, poor panel placement, or extended sub-freezing or overcast conditions.
- The solar system is working, but the end device has an issue.
- The battery has lost significant capacity.
- The solar panel has failed. This is very rare, but possible.
We review several common scenarios based on system indicator lights (a technician must be present) and the dashboard using our IoT module.
System Indicator Lights
Section titled “System Indicator Lights”| Color | Pattern | Meaning |
|---|---|---|
| Green | Solid | System on, not charging |
| Flashing slow | Charging | |
| Flashing fast | MPPT / fast charging | |
| Amber | Solid | System on |
| Flashing slow | Low battery voltage | |
| Flashing fast | Low voltage protection | |
| Red | Solid | No output |
| Flashing slow | Over temperature | |
| Flashing fast | Short circuit protection |
Using the Dashboard
Section titled “Using the Dashboard”Our CORE Battery Health Monitor is an optional add-on to any CORE solar system. It reports the following variables to a dashboard:
- Solar power to battery (voltage, current, watts)
- Load output to device (voltage, current, watts)
- Battery temperature
- Estimated state of charge (SoC)
If you have multiple devices, they can be arranged in a fleet.
Example 1: Well Sized
Section titled “Example 1: Well Sized”This is an example of a well performing system. It has a 100 watt solar panel and 60Ah battery powering a 3 Watt continuous load (72 watt hours per day) in Northern California.
Each day, the battery charges up fully in a few hours and only loses about 10% of its capacity each day. It could run for about 10 days with no solar input.

Example 2: Undersized
Section titled “Example 2: Undersized”This system is underpowered. It has a 50 Watt solar panel and 18Ah battery powering a 3.3 Watt continuous load (79 watt hours per day) in the southeastern United States. After an extensive rain period from a hurricane, the battery drained and the output was cut off.
In the graph, the green state of charge estimate and the purple load go to zero. After building up a buffer from solar charging, the load turns on again. It repeats this cycle a few times until sunny weather returns.
Switching from the 18Ah V102 to the 60Ah V107 would allow the system to get through 9 days of bad weather. Currently, the system can only run for about 2.5 days with no sun before running out of power.
Increasing the solar panel from 50 watt to 100 watt would help as well.

Example 3: Cold Temperature Dropout
Section titled “Example 3: Cold Temperature Dropout”This shows the solar panel performance in Toronto, Canada during December.
We see the panel voltage peak to about 20V consistently every day, but only 2 of 7 days show any solar charging. In this instance, the temperature is below freezing and the battery is not accepting any charge.

Other Identifiable Issues from the Dashboard
Section titled “Other Identifiable Issues from the Dashboard”- Panel pointed in the wrong direction: power production will be biased towards morning or evening.
- Panel shaded by buildings or trees: power production will show cutoffs during the day or lower values than expected. Often paired with a mapping tool.
- Device needs a reboot: the battery is full and shows high voltage, but zero output.