Specifications
Voltaic designs small solar panels for a wide range of outdoor industrial applications. There are two primary construction techniques for our standard panel line.
ETFE panels are light, thin and waterproof and are often embedded into a hardware device or enclosure. They range in power from 0.3 to 20 watts and come in 2, 4, 6 and 18 volt versions.
Glass panels have a glass top-sheet and aluminum frame and come in 25, 50 and 100 watt sizes, all at 18 volts. These are used in our CORE Solar Systems.
Standard Panel Table
Section titled “Standard Panel Table”Electrical values are nominal: the rated values at Standard Test Conditions. Output in the field is lower. For full performance details see each panel’s technical datasheet.
Standard Test Conditions
Section titled “Standard Test Conditions”Panel electrical ratings (Voc, Isc, Vp, Ip and Wp) are measured at Standard Test Conditions (STC), the reference conditions used by IEC 61215 and every panel datasheet:
- Irradiance of 1,000W/m²
- AM1.5 spectrum (sunlight through 1.5 atmospheres, the reference for mid-latitudes)
- Cell temperature of 25°C
- Light perpendicular to the panel
A deployed panel rarely meets all four at once. Irradiance is usually lower, the cells run hotter or cooler than 25°C, and the panel seldom points straight at the sun. Expect less than the rated power, and use Estimating Power Production to size for a real deployment.
Estimating Power Production
Section titled “Estimating Power Production”The expected peak power from the solar panel is listed in each technical drawing. This is the power produced at Standard Test Conditions:
We use the PVGIS tool to estimate the available energy and shademap.app to estimate the effect of shading by buildings or trees.
To estimate usable energy, you also need to discount this value by your:
- Circuit efficiency
- Energy lost into your storage element
We use two free tools to estimate available energy on a solar panel and potential shading impacts.
- PVGIS (opens in a new tab) gives the daily energy a panel produces at a location for a given angle and azimuth, by month. Size for the worst months, which are December and January in the northern hemisphere. The Voltaic blog has a step-by-step guide to PVGIS for IoT devices (opens in a new tab).
- shademap.app (opens in a new tab) shows how many hours of direct sun a spot receives on a given date, so you can discount the PVGIS figure for trees and buildings and compare alternative spots.
Panel Angle
Section titled “Panel Angle”The panel angle affects how much energy the solar panel generates during different times of the year. This choice also has different physical design implications.
| Position | Advantages | Disadvantages |
|---|---|---|
| Vertical (90°) | No snow buildup; limits biofouling; takes little horizontal space | Lower power if not facing south; low power in summer |
| Horizontal (0°) | Works in any device orientation | Low power in winter; most exposed to snow buildup and biofouling |
| Angled 30–70° | Highest power when facing south | Must be pointed the right way; sticks out from the enclosure |
Example 1: Fixed Unshaded Agricultural Gateway
Section titled “Example 1: Fixed Unshaded Agricultural Gateway”Assume you are considering the 2.6W P126 (opens in a new tab) for a low-power gateway in an agricultural application. The panel will be pointed South with no obstructions. You are considering placing the panel flat on top of the enclosure, at a 60° angle or vertical. You believe most of your customers will be in the central United States, between Texas and North Dakota.
From the technical drawing, the P126 has an expected peak power of 2.21W.
Using PVGIS, you can evaluate the energy generated per day at the summer and winter solstices in Dallas, Texas (southern US) and Bismarck, North Dakota (northern US) in the three positions.
Average energy per day from a south-facing P126 (Wh)
| Site | Vertical | Horizontal | Angled 60° | |||
|---|---|---|---|---|---|---|
| June | December | June | December | June | December | |
| Dallas, TX | 2.7 | 6.2 | 10.1 | 3.9 | 6.3 | 7.0 |
| Bismarck, ND | 4.4 | 5.1 | 10.4 | 2.1 | 5.2 | 5.2 |
This table shows the average energy the panel can produce per day if it is held at its maximum power point.
The angled panel provides the most consistent energy across locations and seasons. The horizontal panel performs worst in Bismarck in winter, and the vertical panel performs worst in Dallas in June.
The energy available to your device will be slightly lower, because:
- most low-power solar circuits don’t have perfect maximum power point tracking; a buck converter is typically about 90% efficient
- energy is lost as power goes from electrical to chemical energy in your storage element.
Example 2: Fixed Partially Shaded Air Quality Monitor
Section titled “Example 2: Fixed Partially Shaded Air Quality Monitor”Assume you are placing the 5.9W P105 (opens in a new tab) in Sheep Meadow, Central Park, to power an air quality monitoring station. The approved location is in the southeast corner, and it looks sunny when you visit on a June afternoon. The technical drawing shows an expected peak power of 4.96W, and the panel sits at 45° on the BK102 bracket.
According to PVGIS, the panel could produce an average of 11.9Wh per day in December.

On shademap.app, you look at the expected shadows from trees in December. This is when the sun is at its lowest and you see significant shadows from the trees in the southeast corner.

In December, nearby rooftops get 9 hours of sunlight per day. The southeast corner of the meadow gets 4 hours (light green) and the northeast corner closer to 7 (green and red).
Moving the station to the northeast corner will increase the energy the panel produces. Either way, it will be less than the 11.9Wh estimated by PVGIS. The actual number is hard to estimate exactly, but is likely to be 40 to 70% of that value depending on the location.

Example 3: Varying Orientation Livestock Tracker
Section titled “Example 3: Varying Orientation Livestock Tracker”Assume you are evaluating the 0.7W P123 (opens in a new tab) for a tracking application. It will be placed on the side of a vehicle (vertical) or on the ear of a cow, and could be facing in any direction as it moves through the day.
From the technical drawing, the expected peak power at Standard Test Conditions is 0.60W. If the vehicle moves throughout the country, you can get a baseline by averaging the energy facing each direction.
Average energy per day from a vertical P123 in Omaha, Nebraska in December, mixed orientation (Wh)
| South | East | West | North | Average |
|---|---|---|---|---|
| 0.82 | 0.28 | 0.28 | 0.07 | 0.36 |
At scale, testing from a pilot will give more exact numbers. Until then, 0.36Wh per day from a 0.6W panel mounted vertically on a rotating object is a good baseline for the maximum daily energy available before it enters the circuit.
Solar Panel Cleaning
Section titled “Solar Panel Cleaning”The ETFE top layer on most Voltaic solar panels has very low surface energy, which keeps most debris from building up on the panel.
If dust does build up on the panel, we observe power losses of about 10%.
At small scale, clean panels with isopropyl alcohol or soapy water.
Customers regularly clean vehicles with Voltaic solar panels mounted on them using pressure washers.