Voltaic’s standard solar panel stack consists of an ETFE (ethylene tetrafluoroethylene) front sheet, EVA (ethylene-vinyl acetate) encapsulant, the solar cells and a PCB substrate. They are are qualified in the field and in laboratory stress tests to IEC, SAE, MIL-STD and AAR standards. For the conditions or results of a test, contact us (opens in a new tab).

TestStandard
Accelerated aging (heat, humidity, UV)IEC 61215 MQT 08
Accelerated aging (heat, humidity, UV)Self-specified
Damp heatIEC 61215 MQT 13
Humidity freezeSAE J1455 (2017) 4.2.3, Fig. 4A
Humidity freezeSelf-specified
Thermal cyclingIEC 61215 MQT 11
Thermal shockSAE J1455 (2017) 4.1.3.2
TestStandard
Handling dropSAE J1455 (2017) 4.10.3.1
ImpactIEC 62262 IK08 and IK09
Mechanical shockSAE J1455 (2017) 4.10
Mechanical shockMIL-STD-810H Method 516.8, Procedure I
Random vibrationSAE J1455 (2017) 4.5
Random vibrationAAR S-9401 3.2.4.2 and Table 3.3
Sinusoidal vibrationSAE J1455 (2017) Appendix A
Sinusoidal vibrationAAR S-9401 3.2.4.1 and Table 3.3
TestStandard
Chemicals and oilsSAE J1455 (2017) 4.4.3.2
Dust and sand (IP6X)IEC 60529 (2001) 13.4 and 13.6.2
Ingress, immersion (IPX7)IEC 60529 (2001) 14.2.7; ISO 20653 (2013) Table 7, Fig. 7
Ingress, pressure wash (IPX9K)IEC 60529
Salt spray (fog)SAE J1455 (2017) 4.3.3.1 (refers to ASTM B117)
Salt water immersionSAE J1455 (2017) 4.3.3.2
Water immersionSelf-specified

ATEX is the EU framework for equipment used in potentially explosive atmospheres. Voltaic’s SMT (surface-mount) ETFE panels have been integrated into devices that have passed two ATEX testing standards:

AtmosphereMarking
GasII 2G Ex ib IIB T4 Gb
DustII 2D Ex ib IIIB T135°C Db

Tests marked “Self-specified” follow Voltaic’s own profile. The other tests follow these standards:

StandardWhat it covers
AAR S-9401 (opens in a new tab)The Association of American Railroads’ environmental requirements for railroad electronics, part of its Manual of Standards and Recommended Practices. It sets the conditions, including vibration, that electronics on rail equipment must withstand.
ASTM B117 (opens in a new tab)The standard practice for running a salt spray (fog) test: a controlled 5% salt fog used to compare corrosion resistance. The product specification sets how long the exposure lasts.
ATEX (Directive 2014/34/EU) (opens in a new tab)The EU directive for equipment and protective systems used in potentially explosive atmospheres, in force since 20 April 2016. See ATEX Certification above.
IEC 60529 (opens in a new tab)The IP code, which rates an enclosure’s protection against solid objects and dust (first digit) and against water (second digit). For example, IP6X is dust-tight and IPX7 survives temporary immersion.
IEC 61215 (opens in a new tab)The international standard for design qualification and type approval of solar (PV) modules for long-term outdoor use. Its individual tests are numbered as module quality tests (MQT), such as MQT 11 for thermal cycling and MQT 13 for damp heat.
IEC 62262 (opens in a new tab)The IK code, which rates an enclosure’s protection against mechanical impact, from IK00 (no protection) to IK10 (20J).
ISO 20653 (opens in a new tab)The IP code for electrical equipment on road vehicles. It adds “K” ratings such as IPX9K: a high-pressure jet of hot water at about 80°C.
MIL-STD-810H (opens in a new tab)The US Department of Defense’s standard for environmental engineering and laboratory tests. Method 516.8 covers mechanical shock during handling, transport and use.
SAE J1455 (opens in a new tab)SAE’s recommended environmental practices for designing electronics for heavy-duty vehicles: on- and off-road trucks, trailers, buses, and construction and agricultural equipment. It covers the climatic, mechanical and electrical conditions the electronics must survive.